MODEL 2401-EW END WINDOW POCKET SURVEY METER

Click here to return to INSTRUMENT SALES

PART NUMBER:48-2874
DETECTOR: 0.566" diameter end window G-M
SENSITIVITY: Typically 1050 cpm/mR/hr
ENERGY RESPONSE: Energy dependant
METER DIAL: 0 - 2 mR/hr; 0 - 2.1k cpm; BAT OK
MULTIPLIERS: X1, X10, X100
LINEARITY: Reading within plus or minus 10% of true value
AUDIO: Built in unimorph speaker (select quiet position on main switch to silence the audio)
CALIBRATION CONTROLS: Accessible from front of instrument
RESPONSE: Typically 5 seconds from 10% to 90% of final reading
POWER: 1 ea. 9 volt
BATTERY LIFE: Typically 250 hours with alkaline batteries (battery condition can be checked on meter )
METER: 2.5" (6.4 cm) arc, 1 mA analog type
CONSTRUCTION: Aluminum housing with beige polyurethane enamel paint, and a recessed subsurface printed membrane front panel
TEMPERATURE RANGE: -4 degrees F(-20 degrees C) to 122 degrees F(50 degrees C) 
May be certified for operation from -40 degrees F(-40 degrees C) to 150 degrees F(65 degrees C)
SIZE: 1.8" (4.6 cm)H X 3.3" (8.4 cm)W X 5.3" (13.5 cm)L
WEIGHT: 0.9 lbs (0.4 kg) including batteries